Mitsubishi Electric MDS-E Series Instruction Manual page 337

Table of Contents

Advertisement

MDS-E/EH Series Instruction Manual
5 Servo Adjustment
[6] Spindle drive unit in the 2nd part system controls power supply unit.
Vertical axis is a 2-axis unit in the 1st part system (vertical axis: Z axis).
NC
(1st part system)
NC
(2nd part system)
Axis other than the
Axis
Parameter
SV048
SV055
SV056
(Note)
For the standard setting value of SV056, refer to "Deceleration control".
CAUTION
In the 2nd part system of the power supply, if the axis for vertical axis drop prevention is connected with the CN9 connector
of the power supply unit, provide the vertical axis drop prevention control setting also for the drive unit connected with CN4
connector of the same power supply unit.
IB-1501229-F
MDS-E/EH-V1
MDS-E/EH-V2
right
MDS-E/EH-V1,V2
Same value
0
as Z axis ->
Each axis Maximum value of SV056 setting value +100ms
Standard setting value for each axis (Note)
MDS-E/EH-V2
MDS-E/EH-V2
Y axis, *Z axis
MDS-E/EH-SP
Spindle
Y axis
Z axis (Vertical axis)
MDS-E/EH-V2
200ms as a standard
(Set by adjustment)
306
MDS-E/EH-CV
Power supply
Spindle
MDS-E/EH-SP
Set as follows.
SP055=5000
SP056=300

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents