MDS-E/EH Series Instruction Manual
1 Installation
1.1.6 Machine Accuracy
Machine accuracy of the servo motor's output shaft and around the installation part is as below.
(Excluding special products)
Accuracy
Run-out of the flange surface to
the output shaft
Run-out of the flange surface's
fitting outer diameter
Run-out of the output shaft end
IB-1501229-F
Measurement
point
Less than 100 SQ.
a
0.05mm
b
0.04mm
c
0.02mm
c
b
6
Flange size [mm]
100 SQ., 130 SQ.
176 SQ. - 250 SQ.
0.06mm
0.08mm
0.04mm
0.06mm
0.02mm
0.03mm
a
280 SQ. or over
0.08mm
0.08mm
0.03mm