MDS-E/EH Series Instruction Manual
4 Setup
【#2236(PR)】 SV036 PTYP Power supply type
bit F-C : amp
Set the power backup function to be used.
No function used : 0
Deceleration and stop function at power failure : 8
Retraction function at power failure : C
bit 7-0 : ptyp External emergency stop setting
When the emergency stop input signal of the power supply unit is "disabled"
Power supply unit is not connected : 0000h
MDS-E-CV-37 / MDS-EH-CV-37
MDS-E-CV-75 / MDS-EH-CV-75
MDS-E-CV-110 / MDS-EH-CV-110
MDS-E-CV-185 / MDS-EH-CV-185
MDS-E-CV-300 / MDS-EH-CV-300
MDS-E-CV-370 / MDS-EH-CV-370
MDS-E-CV-450 / MDS-EH-CV-450
MDS-E-CV-550 / MDS-EH-CV-550
When the emergency stop input signal of the power supply unit is "enabled"
(Note) Set the power supply rotary switch to "4".
Power supply unit is not connected
MDS-E-CV-37 / MDS-EH-CV-37
MDS-E-CV-75 / MDS-EH-CV-75
MDS-E-CV-110 / MDS-EH-CV-110
MDS-E-CV-185 / MDS-EH-CV-185
MDS-E-CV-300 / MDS-EH-CV-300
MDS-E-CV-370 / MDS-EH-CV-370
MDS-E-CV-450 / MDS-EH-CV-450
MDS-E-CV-550 / MDS-EH-CV-550
(3) Parameter set for C80 system
For C80 system, set the parameter as to ignore unnecessary alarm histories that is recorded when the NC power is
turned OFF.
【#2314】 SV114 SSF9 Servo function 9
bit 8 : nohis History of communication error alarm between NC and DRV (34, 36, 38, 39)
0: Enable
: 0004h
: 0008h
: 0011h
: 0019h
: 0030h
: 0037h
: 0045h
: 0055h
MDS-EH-CV-750
: 0075h
: 0000h
: 0044h
: 0048h
: 0051h
: 0059h
: 0070h
: 0077h
: 0085h
: 0095h
MDS-EH-CV-750
: 00B5h
1: Disable
117