MDS-E/EH Series Instruction Manual
1 Installation
(2) When a gear box is installed on the servo motor, make sure that the oil level height from the center of the shaft is higher
than the values given below. Open a breathing hole on the gear box so that the inner pressure does not rise.
Series
200V
series
400V
series
(3) When installing the servo motor horizontally, set the connector to face downward. When installing vertically or on an
inclination, provide a cable trap because the liquid such as oil or water may enter the motor from the connector by
running along the cable.
Servo motor
HG46, 56
HG96
HG75, 105
HG54, 104, 154, 224, 123, 223, 142
HG204, 354, 303, 453, 703, 302
HG903
HG-H75, 105
HG-H54, 104, 154
HG-H204, 354, 453, 703
HG-H903
HG-H1502
HQ-H903, 1103
Gear
Oil level
Lip
Oil seal
Cable trap
9
Oil level (mm)
12.5
15
15
22.5
30
34
15
22.5
30
34
45
30
Servo motor
IB-1501229-F