6 Spindle Adjustment
【#13226】 SP226 SFNC6 Spindle function 6
bit 8 : r2c Temperature compensation adjustment indicator
0: Normal 1: Display
【#13235(PR)】 SP235 R2H Temperature compensation gain
Set the magnification in converting the thermistor temperature to the control compensation amount.
When "0" is set, the temperature compensation function is disabled.
When not using, or when using an IPM spindle motor, set to "0".
---Setting range---
0 to 400 (%)
【#13236(PR)】 SP236 WIH Temperature compensation time constant
Set the delay time constant from the thermistor temperature to the control compensation amount.
When "0" is set, the delay time constant is disabled.
When not using, or when using an IPM spindle motor, set to "0".
---Setting range---
0 to 150 (min)