MDS-E/EH Series Instruction Manual
4 Setup
#2261
SV061 DA1NO
Input the data number you wish to output to the D/A output channel 1.
When using the 2-axis drive unit, set "-1" to the axis that the data will not be output.
When the DC excitation is running (SV034/bit4=1):
Use this when the DC excitation is running (SV034/bit4=1) to adjust the initial magnetic pole position
(when measuring the magnetic pole shift amount) for linear motor and direct-drive motor.
Set the initial excitation level in DC excitation control.
Set 10% as standard.
Related parameters: SV062, SV063
---Setting range---
-32768 to 32767
When the DC excitation is running (SV034/bit4=1): 0 to 100 (Stall current %)
#2262
SV062 DA2NO
Input the data number you wish to output to the D/A output channel 2.
When using the 2-axis drive unit, set "-1" to the axis that the data will not be output.
When the DC excitation is running (SV034/bit4=1):
Use this when the DC excitation is running (SV034/bit4=1) to adjust the initial magnetic pole position
(when measuring the magnetic pole shift amount) for linear motor and direct-drive motor.
Set the final excitation level in DC excitation control.
Set 10% as standard.
When the magnetic pole shift amount measurement value is unsteady, adjust the value in increments of
5%.
Related parameters: SV061, SV063
---Setting range---
-32768 to 32767
When the DC excitation is running (SV034/bit4=1): 0 to 100 (Stall current %)
#2263
SV063 DA1MPY
Set output scale of the D/A output channel 1 in increment of 1/100.
When "0" is set, the magnification is the same as when "100" is set.
When the DC excitation is running (SV034/bit4=1):
Use this when the DC excitation is running (SV034/bit4=1) to adjust the initial magnetic pole position
(when measuring the magnetic pole shift amount) for linear motor and direct-drive motor.
Set the initial excitation time in DC excitation control.
Set 1000ms as standard.
When the magnetic pole shift amount measurement value is unsteady, adjust the value in increments of
500ms.
Related parameters: SV061, SV062
---Setting range---
-32768 to 32767 (1/100-fold)
When the DC excitation is running (SV034/bit4=1): 0 to 10000 (ms)
#2264
SV064 DA2MPY
Set output scale of the D/A output channel 2 in increment of 1/100.
When "0" is set, the magnification is the same as when "100" is set.
---Setting range---
-32768 to 32767 (1/100-fold)
D/A output ch1 data No. / Initial DC excitation level
D/A output ch2 data No. / Final DC excitation level
D/A output ch1 output scale / Initial DC excitation time
D/A output ch2 output scale
151
IB-1501229-F