<Outline of system configurations and corresponding parameter settings>
[1] Spindle drive unit controls power supply unit. Vertical axis is a 1-axis unit (vertical axis: Z axis).
NC
Axis
Parameter
SV048
SV055
SV056
(Note)
For the standard setting value of SV056, refer to "Deceleration control".
[2] Spindle drive unit controls power supply unit. Vertical axis is a 2-axis unit (vertical axis: Z axis).
NC
Axis
Parameter
SV048
SV055
SV056
(Note)
For the standard setting value of SV056, refer to "Deceleration control".
MDS-E/EH-V2
MDS-E/EH-V1
X axis, Y axis
*Z axis
X axis
Y axis
MDS-E/EH-V2
0
X, Y, Z axis Maximum value of SV056 setting value +100ms
Standard setting value for each axis (Note)
MDS-E/EH-V1
MDS-E/EH-V2
X axis
Y axis, *Z axis
X axis
Y axis
MDS-E/EH-V1
Same value
0
as Z axis ->
X, Y, Z axis Maximum value of SV056 setting value +100ms
Standard setting value for each axis (Note)
MDS-E/EH-SP
MDS-E/EH-CV
Spindle
Power supply
Z axis (Vertical axis)
MDS-E/EH-V1
200ms as a standard
0
(Set by adjustment)
MDS-E/EH-SP
MDS-E/EH-CV
Spindle
Power supply
Z axis (Vertical axis)
MDS-E/EH-V2
200ms as a standard
(Set by adjustment)
303
Spindle
MDS-E/EH-SP
Set as follows.
SP055=5000
SP056=300
Spindle
MDS-E/EH-SP
Set as follows.
SP055=5000
SP056=300