Alarm No.
Power supply: Power module overheat
77
Thermal protection function in the power module has started its operation.
Investigation details
1
Confirm that the fan is properly rotating.
2
Check whether the heat dissipating fins are dirty.
Measure the power supply unit's ambient
3
temperature.
Check if there is any abnormality in the unit's
4
ambient environment.
(Ex. Ambient temperature, noise, grounding)
Alarm No.
Main side encoder cable error
80
A pulse type cable is used for the motor side encoder.
Investigation details
Check the parameters.
Servo:SV025 = "x200"
1
Spindle:SP031 = "x200"
And then, check the connected cable and the
encoder.
IB-1501229-F
Investigation results
Large amounts of cutting oil or cutting chips,
etc., are adhered, or the rotation is slow.
The fan is properly rotating.
Cutting oil or cutting chips, etc., are adhered,
and the fins are clogged.
The fins are normal.
55°C or more
Less than 55°C.
Take remedies according to the causes of the abnormality in the ambient environment.
Investigation results
The cable type is pulse.
There is no problem with the selection of the
encoder and cable.
412
Remedies
Clean or replace the fan.
Check the investigation item No. 2.
Clean the fins.
Check the investigation item No. 3.
Improve the ventilation and cooling for the
power distribution panel.
Check the investigation item No. 4.
Remedies
Replace the cable to the serial type.
Replace the encoder or cable.