MDS-E/EH Series Instruction Manual
4 Setup
#13201-
SP201-SP224
13224
Not used. Set to "0".
#13225
SP225 SFNC5
Select the spindle functions.
Functions are allocated to each bit.
Set this in hexadecimal format.
bit F-C: ovsn Overshooting compensation type 3 non-sensitive band
Set the non-sensitive band of the overshooting compensation type 3 in increments of 2°/1000.
In the feed forward control, set the non-sensitive band for the model position droop and ignore the model
overshooting. Set to "2°/1000" as a standard.
bit B-9:
Not used. Set to "0".
bit 8: mken Coil switch allowance in deceleration control
This enables a coil changeover while decelerating after an emergency stop for a spindle motor with coil
changeover specification. A coil changeover may enable an excessive load inertia to stop within the maxi-
mum delay time.
0: Normal (Disable)
1: Enable
bit 7-6: thno
Select the thermistor characteristics.
When SP225/bit3=0 (N type) is selected
bit7,6=
00: For Mitsubishi spindle motor
01: Setting prohibited
10: Setting prohibited
11: Setting prohibited
When SP225/bit3=1 (P type) is selected
bit7,6=
00: KTY84-130 (Manufactured by Philips)
01: Setting prohibited
10: Pt1000 (Platinum resistance temperature detector)
11: Setting prohibited
bit 5: ddir Proximity switch signal enable edge
0: Falling edge 1: Rising edge
bit 4: dcd DC excitation mode
0: Normal 1: Start
bit 3: thtyp
Select the thermistor type.
0: Type N thermistor (Mitsubishi standard)
1: Type P thermistor or platinum resistance temperature detector
bit 2: mohn Thermistor temperature detection
0: Normal 1: Disable (Except for TS5690/5691)
bit 1-0:
Not used. Set to "0".
IB-1501229-F
Spindle function 5
mohn
thtyp
dcd
ddir
thno
mken
ovsn
240