Mitsubishi Electric MDS-E Series Instruction Manual page 107

Table of Contents

Advertisement

MDS-E/EH Series Instruction Manual
2 Wiring and Connection
(2) Connecting the spindle side ABZ pulse output encoder (OSE-1024-3-15-68, OSE-1024-3-15-68-8)
Spindle motor
Spindle
(Note)
Confirm that the gear ratio (pulley ratio) of the spindle end to the encoder is 1:1. Use a timing belt for
connecting.
(3) Connecting the spindle side PLG serial output encoder (TS5690)
Spindle motor
Spindle
Spindle side accuracy encoder
IB-1501229-F
CNP2E-1 cable
max. 30m
CNP3EZ cable
max. 30m
Spindle side encoder
CNP2E-1 cable
max. 30m
TS5690 series
CNP2E-1 cable
max. 30m
MDS-E/EH-SP
CN2L
CN3L
MDS-E/EH-SP
CN2L
CN3L
76
Encoder connector : CN3L
Pin No.
No.9
No.1
No.10 No.2
Pin
Name
Pin
Name
P5(+5V)
1
2
LG
3
A
4
A*
5
B
6
B*
7
Z
8
Z*
9
10
ABZSEL*
Encoder connector : CN3L
Pin No.
 
No.9
No.1
No.10 No.2
Pin
Name
Pin
Name
P5(+5V)
1
2
LG
3
RQ
4
RQ*
5
6
7
SD
8
SD*
9
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents