MDS-E/EH Series Instruction Manual
4 Setup
#2315
SV115 SSF10
Select the servo functions.
A function is assigned to each bit.
Set this in hexadecimal format.
bit F : are Notch filter5 all frequencies adapted
When enabled, Notch filter5 all frequencies adaptive range is not limited regardless of SV115/bit4,5 setting.
0: Disable
bit E-C: dsl Notch filter frequency display
Switch the "AFLT frequency" display on drive monitor screen to check every notch filter frequency.
When the selected notch filter is not used, "0" is displayed.
bitE,D,C=
000 : Estimated resonance frequency (Normal display)
001 : Notch filter 1 frequency
010 : Notch filter 2 frequency
011 : Notch filter 3 frequency (always displays 1125Hz)
100 : Notch filter 4 frequency
101 : Notch filter 5 frequency
Other settings: setting prohibited
bit B : ade5 Notch filter 5 / Adaptive follow-up function
0: Disable
bit A : ade4 Notch filter 4 / Adaptive follow-up function
0: Disable
bit 9 : ade2 Notch filter 2 / Adaptive follow-up function
0: Disable
bit 8 : ade1 Notch filter 1 / Adaptive follow-up function
0: Disable
bit 7-6 : dsn Estimated resonance frequency display holding time
Set the estimated resonance frequency display holding time to the "AFLT frequency" display on drive monitor
screen.
bit7,6=
00: 4 [s]
01: 8 [s]
10: 12 [s]
11: 16 [s]
1: Enable
1: Enable
1: Enable
1: Enable
1: Enable
Servo function 10
esn
dfhz
dsn
ade1
ade2
ade4
ade5
dsl
are
159
IB-1501229-F