Setting The Output Magnification; Servo Drive Unit Settings - Mitsubishi Electric MDS-E Series Instruction Manual

Table of Contents

Advertisement

MDS-E/EH Series Instruction Manual
11 Appx. 2: D/A Output Specifications for Drive Unit

11.3 Setting the Output Magnification

11.3.1 Servo Drive Unit Settings

Set when outputting other than the standard output unit. When "0" is set, the magnification will be the same as "100".
(Example 1) When SV061=1 and SV063=50
The motor rotation speed is output at 2000(r/min)/V.
(Example 2) When SV062=3 and SV064=50
The torque feedback is output to D/A output channel 2 with 200%/V unit.
【#2263】 SV063 DA1MPY D/A output ch1 output scale
Set output scale of the D/A output channel 1 in increment of 1/100.
When "0" is set, the magnification is the same as when "100" is set.
---Setting range---
-32768 to 32767 (1/100-fold)
【#2264】 SV064 DA2MPY D/A output ch 2 output scale
Set output scale of the D/A output channel 2 in accruement of 1/100.
When "0" is set, the magnification is the same as when "100" is set.
---Setting range---
-32768 to 32767 (1/100-fold)