4 Setup
#13125
SP125 DA1NO
Input the desired data number to D/A output channel.
When using the 2-axis drive unit, set "-1" to the axis that the data will not be output.
When the DC excitation is running:
Use in the DC excitation function.
DC excitation: Set the initial excitation level when SP225/bit4=1.
When "0" is set, the state will be the same as when "20" is set.
---Setting range---
-32768 to 32767
#13126
SP126 DA2NO
Input the desired data number to D/A output channel.
When using the 2-axis drive unit, set "-1" to the axis that the data will not be output.
When the DC excitation is running:
Use in the DC excitation function.
DC excitation: Set the final excitation level when SP225/bit4=1.
When "0" is set, the state will be the same as when "50" is set.
---Setting range---
-32768 to 32767
#13127
SP127 DA1MPY
Set the output scale in increments of 1/100.
When "0" is set, the scale is the same as when "100" is set.
When the DC excitation is running:
Use in the DC excitation function.
DC excitation: Set the initial excitation time when SP225/bit4=1.
When "0" is set, the state will be the same as when "10000" is set.
---Setting range---
-32768 to 32767 (1/100-fold)
#13128
SP128 DA2MPY
Set the output scale in increments of 1/100.
When "0" is set, the scale is the same as when "100" is set.
---Setting range---
-32768 to 32767 (1/100-fold)
(PR)
#13129-
SP129-SP141
13141
Set the unique constants for the spindle motor. (High-speed coil)
The setting value is determined by the motor's mechanical and electrical characteristics and specifications,
so normally set the value given in the spindle parameter list.
(PR)
#13142
SP142
Set the unique constants for the spindle motor. (High-speed coil)
The setting value is determined by the motor's mechanical and electrical characteristics and specifications,
so normally set the value given in the spindle parameter list.
For IPM spindle motor
This parameter is used in initial magnetic pole detection of IPM spindle motor.
(1) Pulse application time: Set it in [μs] unit.(0 < application time < 350)
(2) Pulse application coil: To select a low-speed coil, add 1000 to the pulse application time.
(3) Polarity of estimated magnetic pole: When it is set to the reverse polarity, add "-" to the total of (1) and (2).
E.g.: When performing 333μs pulse-applied magnetic pole estimation in a low-speed coil and selecting the
reverse polarity for the estimated polarity
SP142 = -(333+1000) = -1333
D/A output ch1 data No. / Initial DC excitation level
D/A output ch2 data No. / Final DC excitation level
D/A output ch1 output scale / Initial DC excitation time
D/A output ch2 output scale
237
IB-1501229-F