MDS-E/EH Series Instruction Manual
4 Setup
#2282
SV082 SSF5
Select the servo functions.
A function is assigned to each bit.
Set this in hexadecimal format.
bit F-C:
Not used. Set to "0".
bit B-A: dos3 Digital signal output 3 selection
bitB,A=
00: Disable
01: Setting prohibited
10: Contactor control signal output (For MDS-EJ/EJH)
11: Setting prohibited
bit 9-8: dos2 Digital signal output 2 selection
bit9,8=
00: Disable
01: Specified speed output
10: Setting prohibited
11: Setting prohibited
bit 7-3:
Not used. Set to "0".
bit 2: ccu Lost motion overshoot compensation compensation amount setting increment
0: Stall current %
bit 1: lmc3 Lost motion compensation type 3
Set this when protrusion at a quadrant change is too big.
0: Stop
1: Start
Related parameters: SV016, SV041, SV085, SV086
bit 0:
Not used. Set to "0".
Servo function 5
1: Stall current 0.01%
153
lmc3
ccu
dos2
dos3