MDS-E/EH Series Instruction Manual
2 Wiring and Connection
(3) Connecting the linear scale (for rectangular wave signal output)
Rectangular wave signal output (including when SIN wave signal output is converted to the rectangular wave signal
output with a scale manufacturer encoder interface unit) can directly input to the drive unit.
Linear scale
( Rectangular wave signal output )
(4) Connecting the linear scale (for SIN wave signal output)
SIN wave signal output is converted to Mitsubishi serial signal output with the encoder interface unit (MDS-EX-HR).
The distance-coded reference scale interface is also available.
Linear scale
( SIN wave signal output )
IB-1501229-F
CNV2E cable
Max. 30m
Servomotor
Cable prepared by user
Max. 30m
CNV2E cable
Max. 30m
CNV2E-HP
Max. 30m
Servomotor
Cable
prepared
MDS-EX-HR
by user
Encoder conversion unit
72
MDS-E/EH-V1
Encoder connector : CN3L
Pin
1
P5(+5V)
CN2L
3
5
7
9
CN3L
Encoder type setting
SV025=82xx
MDS-E/EH-V1
Encoder connector : CN3L
Pin
1
P5(+5V)
CN2L
3
5
7
9
CN3L
cable
Encoder type setting
SV025=A2xx
Pin No.
No.9
No.1
No.10 No.2
Name
Name
Pin
LG
2
A*
A
4
B
B*
6
Z
Z*
8
10
ABZSEL*
Pin No.
No.9
No.1
No.10 No.2
Name
Name
Pin
2
LG
RQ
4
RQ*
6
SD
8
SD*
10