Mitsubishi Electric MDS-E Series Instruction Manual page 272

Table of Contents

Advertisement

MDS-E/EH Series Instruction Manual
4 Setup
#13226
SP226 SFNC6
Select the spindle functions.
Functions are allocated to each bit.
Set this in hexadecimal format.
bit F :
Not used. Set to "0".
bit E : obs Disturbance observer
0: Normal 1: Enable
bit D : vup High response acceleration / deceleration
This suppresses a temporal delay which occurs when the target speed is attained from acceleration and
when the spindle stops from deceleration.
0: Normal acceleration/deceleration 1: High response acceleration/deceleration Enable
bit C : tqof Spindle output stabilization during acceleration
0: Normal 1: Disable
bit B-9 :
Not used. Set to "0".
bit 8 : r2c Temperature compensation adjustment indicator
0: Normal 1: Display
bit 7-6 :
Not used. Set to "0".
bit 5 : pon IPM spindle pulse application magnetic pole estimation
0: Normal 1: Enable
bit 4-0 :
Not used. Set to "0".
Spindle function 6
pon
r2c
tqof
vup
obs
241
IB-1501229-F

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents