(8) Shift the wire rubber packing and wire clamp to the position in the right figure,
and tighten the wire fixed set screw to fix the cable to receptacle case.
Tighten it not to create the space between the receptacle case and wire fixed
set screw.
(Note)
Confirm that the cable is fixed.
(9) To ensure that there is no leaning on the receptacle housing in the receptacle
case assembly, drop the POST BASE for inspection naturally as shown in the
right figure.
Confirm that the space between the receptacle case assembly and the POST
BASE is within 1mm. Regarding POST BASE for inspection, contact with the
sales department of the manufacturer below.
Tyco Electronics Japan G.K. http://www.te.com/en/home.html
(10) Insert the assembled connector until it stick fast to the POST BASE and then,
tighten the four bind screws to fix. The tightening torque of the bind screw is
5.0 to 10.0 N•cm.