6 Spindle Adjustment
(6) Spindle control input 6
Name
Spindle
control input 6
bit0. OMR-FF control request (OMRFF)
[1]
The OMR-FF control which determines the tracking ability to the position command by using scale model
gain is selected with OMRFF=1.
[2]
The tracking ability to the position command is determined by using conventional position loop gain with
OMRFF=0.
bit8. Drivers communication control request (DD1)
[1]
The high-speed synchronous tapping control which allows data communication between drive units is
selected with DD1=1.
[2]
The normal synchronous tapping is selected with DD1=0.
(Note)
The bits other than those above are used for maintenance.
Details
F
E
D
C
B
A
9
8
7
DD1
Details
bit
0
OMRFF
OMR-FF control request
-
1
(For maintenance)
2
-
(For maintenance)
3
-
(For maintenance)
4
-
(For maintenance)
-
(For maintenance)
5
(For maintenance)
6
-
(For maintenance)
7
-
DD1
Drivers communication control request
8
9
-
(For maintenance)
A
-
(For maintenance)
(For maintenance)
B
-
(For maintenance)
C
-
(For maintenance)
D
-
(For maintenance)
E
-
(For maintenance)
F
-
367
6
5
4
3
2
1
0
OMRFF
IB-1501229-F