MDS-E/EH Series Instruction Manual
2 Wiring and Connection

2.3.2 Drive Unit Arrangement

Arrange the drive units in the following procedure.
(1) Install a power supply unit.
(2) Arrange drive units in order of the nominal current from largest from the right.
(3) In the arrangement, the clearance between the units is 1 mm.
(4) Arrange the drive units with the DC connection length from the power supply unit being 1500mm or less.
For the arrangement of 1500mm or more, multiple power supply units are required.
(5) Arrange large capacity drive units at the left of the power supply unit with the clearance between the drive units
being 1mm.
POINT
1. Arrange large capacity drive units at the left of the power supply unit with the clearance between the drive units being
1mm.
2. Power supply units equivalent to the number of large capacity drive units are required.
3. MDS-E-SP-400/640, MDS-EH-SP-200/320/480/600, and MDS-EH-V1-200 are the large capacity drive units.
1mm
Use the dedicated
connection bar.
Arrange drive units in order of nominal current from largest.
1mm
1mm
1500mm or less
Large
65
1mm
Small
IB-1501229-F