Mitsubishi Electric MDS-E Series Instruction Manual page 252

Table of Contents

Advertisement

MDS-E/EH Series Instruction Manual
4 Setup
#13033
SP033 SFNC1
Select the spindle specification.
A function is allocated to each bit.
Set this in hexadecimal format.
bit F-C :
Not used. Set to "0".
bit B-A : ovs Overshoot compensation
Set this parameter when overshooting occurs during positioning.
bitB,A=
00: Compensation stop
01: Setting prohibited
10: Setting prohibited
11: Compensation type 3
Set the compensation amount in SP043(OVS1) and SP042(OVS2).
bit 9-8 : lmc Lost motion compensation type2
Set this parameter when the protrusion at quadrant change is too large.
bit9,8=
00: Compensation stop
01: Setting prohibited
10: Compensation type 2
11: Setting prohibited
Set the compensation amount in SP048(LMC1) and SP041(LMC2).
bit 7 : lmc2a Lost motion compensation 2 timing
0: Normal
bit 6 :
Not used. Set to "0".
bit 5-4 : vfct Jitter compensation pulse number
Suppress vibration by machine backlash when axis stops.
bit5,4=
00: Disable
01: 1 pulse
10: 2 pulse
11: 3 pulses
bit 3-0 :
Not used. Set to "0".
1: Change
Spindle function 1
vfct
221
IB-1501229-F