Mitsubishi Electric MDS-E Series Instruction Manual page 403

Table of Contents

Advertisement

MDS-E/EH Series Instruction Manual
6 Spindle Adjustment
bitB. In minimum excitation rate 2 selection (PY2)
[1]
When PY2=1 is set, the minimum excitation rate 2 (SP015) is being selected.
[2]
When PY2=0 is set, the minimum excitation rate 1(SP014) is being selected.
bitC. In speed gain set 2 selection (VG2)
[1]
When VG2=1 is set, the gain parameter (SP008/SP009/SP010) used in the speed loop isbeing selected.
[2]
When VG2=0 is set, the gain parameter (SP005/SP006/SP007) used in the speed loop isbeing selected.
bitD. Zero point re-detection complete
If the zero point re-detection is completed after the zero point re-detection request (control input5/bitD) is set
to1, ORF=1 is set. If the zero point re-detection request is set to 0, ORF=0 is set.
bitF. In 2nd in-position (INP2)
The status changes to INP2=1 when position droop exists within the in-position area set by parameter SP025
(INP2) regardless of serve ON or OFF.
(Note)
The bits other than those above are used for maintenance.
(6) Spindle control output 6
Name
Spindle
control output 6
bit0. In OMR-FF control (OMRFF)
OMRFF=1 (enabled) if OMR-FF control is enabled.
bit8. In drivers communication control (DD1)
DD1=1 (enabled) if high-speed synchronous tapping control is enabled.
(Note)
The bits other than those above are used for maintenance.
IB-1501229-F
Details
F
E
D
C
B
A
9
8
7
DD1
bit
Details
0
OMRFF
In OMR-FF control
-
1
(For maintenance)
2
-
(For maintenance)
3
-
(For maintenance)
4
(For maintenance)
-
-
(For maintenance)
5
(For maintenance)
6
-
(For maintenance)
7
-
DD1
In drivers communication control
8
9
-
(For maintenance)
A
-
(For maintenance)
B
-
(For maintenance)
(For maintenance)
C
-
(For maintenance)
D
-
(For maintenance)
E
-
(For maintenance)
F
-
6
5
4
3
2
1
0
OMRFF
372