Chapter 3 - Installing, Transporting, and Returning the Spectra
System
This chapter describes the Spectra system's environmental requirements,
packing list, and storage instructions. It also contains the packing list
and installation instructions for the Return Flow Controller, and
instructions for moving and returning the Spectra system. The system
should be installed by a technician thoroughly trained in Spectra system
maintenance.
Chapter 4 - Loading and Removing the Disposable Tubing Set and
Other Common Operations
This chapter contains complete instructions for certain operations
common to most or all Spectra system procedures, including:
Setting up the Spectra system
Installing the correct filler
Loading the disposable tubing set
Starting Rinseback
Removing the disposable tubing set
The procedural guides contain condensed versions of these instructions.
If you are unfamiliar with these operations, follow the detailed
instructions in the Essentials Guide. If you are an experienced operator,
use the condensed versions in the guides as a reference.
Chapter 5 - Software Options and Configuration
This chapter provides detailed information about the Spectra system's
software options. The information is separated into six major sections:
Menu/software navigation basics
Spectra system configuration
Donor/patient data entry
MENU ON/OFF key
®
COBE
Spectra™ Apheresis System • Essentials Guide
VALVE key
CHANGE MODE key
Use the keys on the control panel to enter data and make various
selections when operating the Spectra system. See Figure 2-3 in
Chapter 2 for a diagram of the control panel.
Chapter 6 - Automatic and Manual Modes
This chapter explains how to use the Spectra system in Automatic and
Manual mode and how to control Single-Needle flow during Automatic
and Manual mode.
In Automatic mode, the system automatically sets the pump flow rates
and centrifuge speed according to the apheresis procedure selected, and
controls and monitors the AC infusion to the donor or patient.
In Manual mode, the system does not automatically control the pump
flow rates. If you change a pump flow rate, the system will not adjust the
other pump flow rates, AC infusion rate, or inlet:AC ratio to
accomodate the change. You must make any necessary adjustments
yourself.
Chapter 7 - Alarm Tests
After you prime the disposable tubing set, the Spectra system prompts
you to test alarms that ensure essential safety systems are operational.
This chapter describes the alarm tests and contains instructions for
performing them.
These tests check the operation of the access pressure sensor, return air
detector, return pressure sensor, fluid leak detector, and the centrifuge
door and cover safety system. The Spectra system beeps during some
alarm tests. The tests enhance system safety, but you must still monitor
the donor or patient and the system throughout the apheresis procedure.
Gambro BCT recommends that you perform alarm tests after moving
the Spectra system. Otherwise, perform alarm tests as often as your local
regulations require.