Manuals and User Guides for Gambro Cobe Spectra. We have
1
Gambro Cobe Spectra manual available for free PDF download: Essentials Manual
Gambro Cobe Spectra Essentials Manual (245 pages)
Brand:
Gambro
| Category:
Laboratory Equipment
| Size: 6.56 MB
Table of Contents
Table of Contents
5
Preface
7
The COBE ® Spectra TM Apheresis System Operator's Manual
8
The COBE ® Spectra TM Apheresis System Essentials Guide
8
Warnings, Cautions, Notes, and Tips
11
Indications
13
Contraindications
13
Warnings
13
Cautions
18
Service Information
26
Introduction
27
Spectra System Description
28
Spectra System Components
29
Disposable Tubing Sets
47
Functional Description
48
Installing, Transporting, and Returning the Spectra System
51
Installing the Spectra System
52
Transporting the Spectra System
55
Storing the Spectra System
55
Returning the Spectra System
55
Disposing of the Spectra System
56
Loading and Removing the Disposable Tubing Set and Other Common Operations
57
Setting up the Spectra System
58
Loading the Disposable Tubing Set
60
Priming the Disposable Tubing Set
68
Starting Rinseback
68
Disconnecting the Donor or Patient
70
Removing the Disposable Tubing Set
71
Using the Medisystems Masterguard® Anti-Stick Needle Protector
73
Software Options and Configuration
75
Menu/Software Navigation Basics
76
Spectra System Configuration
76
Donor/Patient Data Entry
80
The MENU ON/OFF Key
82
The VALVE Key
88
The CHANGE MODE Key
91
Automatic and Manual Modes
93
Automatic Mode
94
Manual Mode
95
Single-Needle Flow Control
97
Alarm Tests
99
Performing the Alarm Tests
100
Anticoagulation
103
Terminology
104
System Operation and Anticoagulant Management
104
Fluid Volumes
109
Fluid Shifts
112
Extracorporeal Volume
113
Net Additional Saline Returned to the Donor or Patient
114
General Maintenance
115
Operator Maintenance of the Spectra System
116
Operator Maintenance of the Return Flow Controller
119
Technician Maintenance of the Spectra System and the Return Flow Controller
119
Helpful Hints and Recovery Procedures
121
Overview
122
Correcting an Incorrectly Entered Procedure
124
Using an Alternative Single-Pass Prime Procedure
124
Speeding or Slowing Rinseback
126
Determining Net Additional Saline Returned to the Donor or Patient
126
Calculating Product Bag Tare Weights
126
Calculating Spectra System Fluid Volumes
126
Manually Overriding the Centrifuge Cover and Door Latches
127
Performing Manual Rinseback
128
Resolving Power-Up Tests Failure
129
Repositioning the Access Pressure Sensor Diaphragm
129
Repositioning the Return Pressure Sensor Diaphragm
130
General Alarms and Troubleshooting
133
Safety System
134
Shutdown Alarms
134
Warnings and Operator-Attention Alarms
134
Multiple Alarms
134
Repeated Single-Needle Alarms
134
Warnings and Alarms
135
Alarm Clearing
135
AC Infusion Rate Configuration was Changed Last Run
140
AC Infusion Rate Exceeds (Allowable) Limit(S)
141
Ac Pump Error
142
Access Pressure Error
143
Access Pressure Low
144
ACCESS PRESSURE LOW! Check Access Line and Needle
145
Access Pressure Occlusion Error
146
Access Pressure Sensor DID Not Reach Alarm Limit
147
Access Pressure Sensor Not Zero
148
Air in Inlet Chamber
149
Air in Return Chamber
150
Alarm Test Failed
151
CCM Calibration Failure
151
CCM Not Operational - this Run Only
152
Centrifuge Cover Open
153
Centrifuge Pressure Error
154
Centrifuge Pressure High
155
Centrifuge up to Speed
156
Check the CCM for Proper Loading
157
Collect Pump Error
157
Collect Valve Not Operating Correctly
159
Diagnostic Failure Prevents Operation
160
Disconnect Donor/Patient
160
Donor/Patient Disconnected
161
Ensure Return Flow Scale Is in Prime Position
161
Excessive Load on Centrifuge
162
Excessive Vibrations
163
FAILURE #3: __Display Comm
164
Failure #20
165
Failure #_
166
Failure in -5V Power Supply
167
Fluid Leak in Centrifuge
168
Inlet and Ac Pump Flows Not Balanced
170
Inlet Pump Error
171
Invalid Valve Motion
172
NO Rbcs DETECTED
173
No Saline Seen at Inlet Air Sensor
174
No Saline Seen at Return Air Sensor
175
Out of Anticoagulant
176
Overtorque on
177
Plasma and Collect Pumps Running Faster than Inlet
178
Plasma Collection Volume Exceeds Pump Speed Limit
178
Plasma Pump Error
179
Plasma Valve Not Operating Correctly
180
Power Interrupted
181
Pumps off over 3 Minutes
181
PUMPS off too LONG. Centrifuge Turned off for Donor/Patient
182
PUMPS off too LONG. Centrifuge will Turn off in __ Seconds
182
Ratio Configuration was Changed Last Run
183
Rbcs DETECTED
183
Rbcs LOST
184
Restarting Centrifuge
184
Return Flow too Slow
185
Return Pressure High
186
RETURN PRESSURE HIGH! Check Return Line and Needle
187
RETURN PRESSURE HIGH! Decrease Return Flow Scale
189
Return Pressure Occlusion Error
190
Return Pressure Sensor DID Not Reach Alarm Limit
191
Return Pressure Sensor Not Zero
192
Return Valve Bad - Cannot Do Air Remove
192
Return Valve Position Error
193
Service Mode Enabled
194
Specifications
197
Data Input Limits
209
Parameter Limits
210
The Seal Safe ™ System
213
Seal Safe System Installation
215
Seal Safe System Operation
215
Splash Guards
217
Operator Maintenance
219
Technician Maintenance
222
Specifications
223
Index
235
Advertisement
Advertisement
Related Products
Gambro COBE 2991
Gambro AK 95
Gambro AK 95 S
Gambro Categories
Medical Equipment
Water Filtration Systems
Laboratory Equipment
More Gambro Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL