Special Features; Bypass Option; Sensor Input Option - Danfoss VLT AQUA Drive FC 202 Programming Manual

Hide thumbs Also See for VLT AQUA Drive FC 202:
Table of Contents

Advertisement

Parameter Lists

4.1.26 30-** Special Features

Par.
Parameter description
No. #
30-8* Compatibility (I)
30-81
Brake Resistor (ohm)
4
4

4.1.27 31-** Bypass Option

Par. No. #
31-00
31-01
31-02
31-03
31-10
31-11
31-19

4.1.28 35-** Sensor Input Option

Par. No. #
35-0* Temp. Input Mode
35-00
35-01
35-02
35-03
35-04
35-05
35-06
35-1* Temp. Input X48/4
35-14
35-15
35-16
35-17
35-2* Temp. Input X48/7
35-24
35-25
35-26
35-27
35-3* Temp. Input X48/10
35-34
35-35
35-36
35-37
35-4* Analog Input X48/2
35-42
35-43
35-44
234
Parameter description
Bypass Mode
Bypass Start Time Delay
Bypass Trip Time Delay
Test Mode Activation
Bypass Status Word
Bypass Running Hours
Remote Bypass Activation
Parameter description
Term. X48/4 Temp. Unit
Term. X48/4 Input Type
Term. X48/7 Temp. Unit
Term. X48/7 Input Type
Term. X48/10 Temp. Unit
Term. X48/10 Input Type
Temperature Sensor Alarm Function
Term. X48/4 Filter Time Constant
Term. X48/4 Temp. Monitor
Term. X48/4 Low Temp. Limit
Term. X48/4 High Temp. Limit
Term. X48/7 Filter Time Constant
Term. X48/7 Temp. Monitor
Term. X48/7 Low Temp. Limit
Term. X48/7 High Temp. Limit
Term. X48/10 Filter Time Constant
Term. X48/10 Temp. Monitor
Term. X48/10 Low Temp. Limit
Term. X48/10 High Temp. Limit
Term. X48/2 Low Current
Term. X48/2 High Current
Term. X48/2 Low Ref./Feedb. Value
Danfoss A/S © Rev. 2014-01-21 All rights reserved.
Programming Guide
Default value
App.Dependent
Default value
[0] Drive
30 s
0 s
[0] Disabled
0 N/A
0 h
[0] Disabled
Default value
[60] °C
[0] Not Connected
[60] °C
[0] Not Connected
[60] °C
[0] Not Connected
[5] Stop and trip
0.001 s
[0] Disabled
ExpressionLimit
ExpressionLimit
0.001 s
[0] Disabled
ExpressionLimit
ExpressionLimit
0.001 s
[0] Disabled
ExpressionLimit
ExpressionLimit
4.00 mA
20.00 mA
0.000 N/A
4-set-up
Change
during
operation
1 set-up
TRUE
4-set-up
Change
Conver-
during
sion index
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
2 set-ups
TRUE
4-set-up
Change
Conver-
during
sion index
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Conver-
Type
sion index
-2
Uint32
Type
-
Uint8
0
Uint16
0
Uint16
-
Uint8
0
V2
74
Uint32
-
Uint8
Type
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-3
Uint16
-
Uint8
0
Int16
0
Int16
-3
Uint16
-
Uint8
0
Int16
0
Int16
-3
Uint16
-
Uint8
0
Int16
0
Int16
-5
Int16
-5
Int16
-3
Int32
MG20O702

Advertisement

Table of Contents
loading

Table of Contents