Comm. And Options - Danfoss VLT AQUA Drive FC 202 Programming Manual

Hide thumbs Also See for VLT AQUA Drive FC 202:
Table of Contents

Advertisement

Parameter Lists

4.1.9 8-** Comm. and Options

Par. No. #
Parameter description
8-0* General Settings
8-01
Control Site
8-02
Control Source
4
4
8-03
Control Timeout Time
8-04
Control Timeout Function
8-05
End-of-Timeout Function
8-06
Reset Control Timeout
8-07
Diagnosis Trigger
8-08
Readout Filtering
8-1* Control Settings
8-10
Control Profile
8-13
Configurable Status Word STW
8-14
Configurable Control Word CTW
8-3* FC Port Settings
8-30
Protocol
8-31
Address
8-32
Baud Rate
8-33
Parity / Stop Bits
8-35
Minimum Response Delay
8-36
Max Response Delay
8-37
Maximum Inter-Char Delay
8-4* FC MC protocol set
8-40
Telegram Selection
8-42
PCD Write Configuration
8-43
PCD Read Configuration
8-5* Digital/Bus
8-50
Coasting Select
8-52
DC Brake Select
8-53
Start Select
8-54
Reversing Select
8-55
Set-up Select
8-56
Preset Reference Select
8-7* BACnet
8-70
BACnet Device Instance
8-72
MS/TP Max Masters
8-73
MS/TP Max Info Frames
8-74
"I-Am" Service
8-75
Initialisation Password
8-8* FC Port Diagnostics
8-80
Bus Message Count
8-81
Bus Error Count
8-82
Slave Message Rcvd
8-83
Slave Error Count
210
Programming Guide
Default value
null
null
ExpressionLimit
[0] Off
[1] Resume set-up
[0] Do not reset
[0] Disable
null
[0] FC profile
[1] Profile Default
[1] Profile default
[0] FC
ExpressionLimit
null
null
ExpressionLimit
ExpressionLimit
ExpressionLimit
[1] Standard telegram 1
ExpressionLimit
ExpressionLimit
[3] Logic OR
[3] Logic OR
[3] Logic OR
null
[3] Logic OR
[3] Logic OR
1 N/A
127 N/A
1 N/A
[0] Send at power-up
ExpressionLimit
0 N/A
0 N/A
0 N/A
0 N/A
Danfoss A/S © Rev. 2014-01-21 All rights reserved.
4-set-up
Change
Conver-
during
sion index
operation
All set-ups
TRUE
-
All set-ups
TRUE
-
1 set-up
TRUE
-1
1 set-up
TRUE
-
1 set-up
TRUE
-
All set-ups
TRUE
-
2 set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
1 set-up
TRUE
-
1 set-up
TRUE
0
1 set-up
TRUE
-
1 set-up
TRUE
-
1 set-up
TRUE
-3
1 set-up
TRUE
-3
1 set-up
TRUE
-5
2 set-ups
TRUE
-
2 set-ups
TRUE
-
2 set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
1 set-up
TRUE
0
1 set-up
TRUE
0
1 set-up
TRUE
0
1 set-up
TRUE
-
1 set-up
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
Type
Uint8
Uint8
Uint32
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint16
Uint16
Uint8
Uint16
Uint16
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint32
Uint8
Uint16
Uint8
VisStr[2
0]
Uint32
Uint32
Uint32
Uint32
MG20O702