Parameter Lists
4.1.14 15-** FC Information
Par.
Parameter description
No. #
15-0* Operating Data
15-00 Operating hours
15-01 Running Hours
4
4
15-02 kWh Counter
15-03 Power Up's
15-04 Over Temp's
15-05 Over Volt's
15-06 Reset kWh Counter
15-07 Reset Running Hours Counter
15-08 Number of Starts
15-1* Data Log Settings
15-10 Logging Source
15-11 Logging Interval
15-12 Trigger Event
15-13 Logging Mode
15-14 Samples Before Trigger
15-2* Historic Log
15-20 Historic Log: Event
15-21 Historic Log: Value
15-22 Historic Log: Time
15-23 Historic log: Date and Time
15-3* Alarm Log
15-30 Alarm Log: Error Code
15-31 Alarm Log: Value
15-32 Alarm Log: Time
15-33 Alarm Log: Date and Time
15-34 Alarm Log: Setpoint
15-35 Alarm Log: Feedback
15-36 Alarm Log: Current Demand
15-37 Alarm Log: Process Ctrl Unit
15-4* Drive Identification
15-40 FC Type
15-41 Power Section
15-42 Voltage
15-43 Software Version
15-44 Ordered Typecode String
15-45 Actual Typecode String
15-46 Frequency Converter Ordering No
15-47 Power Card Ordering No
216
Programming Guide
Default value
0 h
0 h
0 kWh
0 N/A
0 N/A
0 N/A
[0] Do not reset
[0] Do not reset
0 N/A
0
ExpressionLimit
[0] False
[0] Log always
50 N/A
0 N/A
0 N/A
0 ms
ExpressionLimit
0 N/A
0 N/A
0 s
ExpressionLimit
0 ProcessCtrlUnit
0 ProcessCtrlUnit
0 %
[0] -
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
Danfoss A/S © Rev. 2014-01-21 All rights reserved.
4-set-up
FC 302
Change
only
during
operation
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
2 set-ups
TRUE
2 set-ups
TRUE
1 set-up
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
Conver-
Type
sion
index
74
Uint32
74
Uint32
75
Uint32
0
Uint32
0
Uint16
0
Uint16
-
Uint8
-
Uint8
0
Uint32
-
Uint16
-3
TimD
-
Uint8
-
Uint8
0
Uint8
0
Uint8
0
Uint32
-3
Uint32
TimeO
0
fDay
0
Uint16
0
Int16
0
Uint32
TimeO
0
fDay
-3
Int32
-3
Int32
0
Uint8
-
Uint8
VisStr[
0
6]
VisStr[
0
20]
VisStr[
0
20]
VisStr[
0
5]
VisStr[
0
40]
VisStr[
0
40]
VisStr[
0
8]
VisStr[
0
8]
MG20O702
Need help?
Do you have a question about the VLT AQUA Drive FC 202 and is the answer not in the manual?