Parameter Lists

4.1.15 16-** Data Readouts

Par.
Parameter description
No. #
16-0* General Status
16-00 Control Word
16-01 Reference [Unit]
4
4
16-02 Reference [%]
16-03 Status Word
16-05 Main Actual Value [%]
16-09 Custom Readout
16-1* Motor Status
16-10 Power [kW]
16-11 Power [hp]
16-12 Motor Voltage
16-13 Frequency
16-14 Motor current
16-15 Frequency [%]
16-16 Torque [Nm]
16-17 Speed [RPM]
16-18 Motor Thermal
16-20 Motor Angle
16-22 Torque [%]
16-3* Drive Status
16-30 DC Link Voltage
16-32 Brake Energy /s
16-33 Brake Energy /2 min
16-34 Heatsink Temp.
16-35 Inverter Thermal
16-36 Inv. Nom. Current
16-37 Inv. Max. Current
16-38 SL Controller State
16-39 Control Card Temp.
16-40 Logging Buffer Full
16-49 Current Fault Source
16-5* Ref. & Feedb.
16-50 External Reference
16-52 Feedback[Unit]
16-53 Digi Pot Reference
16-54 Feedback 1 [Unit]
16-55 Feedback 2 [Unit]
16-56 Feedback 3 [Unit]
16-58 PID Output [%]
16-59 Adjusted Setpoint
16-6* Inputs & Outputs
16-60 Digital Input
16-61 Terminal 53 Switch Setting
16-62 Analog Input 53
16-63 Terminal 54 Switch Setting
16-64 Analog Input 54
16-65 Analog Output 42 [mA]
16-66 Digital Output [bin]
16-67 Pulse Input #29 [Hz]
218
Programming Guide
Default value
0 N/A
0 ReferenceFeedbackUnit
0 %
0 N/A
0 %
0 CustomReadoutUnit
0 kW
0 hp
0 V
0 Hz
0 A
0 %
0 Nm
0 RPM
0 %
0 N/A
0 %
0 V
0 kW
0 kW
0 °C
0 %
ExpressionLimit
ExpressionLimit
0 N/A
0 °C
[0] No
0 N/A
0 N/A
0 ProcessCtrlUnit
0 N/A
0 ProcessCtrlUnit
0 ProcessCtrlUnit
0 ProcessCtrlUnit
0 %
0 ProcessCtrlUnit
0 N/A
[0] Current
0 N/A
[0] Current
0 N/A
0 N/A
0 N/A
0 N/A
Danfoss A/S © Rev. 2014-01-21 All rights reserved.
4-set-up
FC 302
Change
only
during
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
x
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Conver-
Type
sion
index
0
V2
-3
Int32
-1
Int16
0
V2
-2
N2
-2
Int32
1
Int32
-2
Int32
-1
Uint16
-1
Uint16
-2
Int32
-2
N2
-1
Int32
67
Int32
0
Uint8
0
Uint16
0
Int16
0
Uint16
0
Uint32
0
Uint32
100
Uint8
0
Uint8
-2
Uint32
-2
Uint32
0
Uint8
100
Uint8
-
Uint8
0
Uint8
-1
Int16
-3
Int32
-2
Int16
-3
Int32
-3
Int32
-3
Int32
-1
Int16
-3
Int32
0
Uint16
-
Uint8
-3
Int32
-
Uint8
-3
Int32
-3
Int16
0
Int16
0
Int32
MG20O702

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT AQUA Drive FC 202 and is the answer not in the manual?

Table of Contents