System - ABB ACS880 Firmware Manual

Primary control program
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

412 Parameters
No.
Name/Value
95.21
HW options word 2
Bit
Name
0
Dual use
1
SynRM
2
Salient PM
3
LV Synchro
4...15
Reserved
0000b...0111b
95.30
Parallel type list
filter
All types
-3 (380-415V)
-5 (380-500V)
-7 (525-690V)
95.31
Parallel type
configuration
Not selected
[Drive/inverter type]
95.40
Transformation ratio
0.000 ... 100.000
96

96 System

96.01
Language
Not selected
English
ghv Vertriebs-GmbH | Am Schammacher Feld 47 | 85567 Grafing | Telefon + 49 80 92 81 89 0 | info@ghv.de | www.ghv.de
Description
Specifies more hardware-related options that require
differentiated parameter defaults. See parameter
options word
1.
WARNING! After switching any bits in this word,
recheck the values of the affected parameters.
Information
1 = Dual use active. For drives with option +N8200. (Allows higher
output frequencies and frequency reference limits.)
1 = Synchronous reluctance motor used. Affects parameters 25.02,
25.03, 25.15, 99.03, 99.13.
1 = Salient-pole permanent magnet motor used. Affects parameters
25.02, 25.03, 25.15, 99.03, 99.13.
1 = Externally-excited synchronous motor used. Requires a license.
Contact your local ABB representative for more information.
Hardware options configuration word 2.
(Only visible with a BCU control unit)
Filters the list of drive/inverter types listed by parameter
Parallel type
configuration.
All types listed.
-3 (380...415 V) types listed.
-5 (380...500 V) types listed.
-7 (525...690 V) types listed.
(Only visible with a BCU control unit)
Defines the drive/inverter type if it consists of parallel-
connected modules.
If the drive/inverter consists of a single module, leave the
value at
Not
selected.
The drive/inverter does not consist of parallel-connected
modules, or type not selected.
Drive/inverter type consisting of parallel-connected modules.
Defines the ratio of the step-up transformer.
Step-up transformer ratio.
Language selection; access levels; macro selection;
parameter save and restore; control unit reboot; user
parameter sets; unit selection; data logger triggering;
parameter checksum calculation; user lock.
Selects the language of the parameter interface and other
displayed information when viewed on the control panel.
Notes:
• Not all languages listed below are necessarily supported.
• This parameter does not affect the languages visible in the
Drive composer PC tool. (Those are specified under View –
Settings.)
None.
English.
Def/FbEq16
-
95.20 HW
1 = 1
All types
95.31
0
1
2
3
Not selected
0
-
0.000
1000 = 1
-
0
1033

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents