356 Parameters
No.
Name/Value
58.28
EFB act1 type
Auto
Transparent
General
Torque
Speed
Frequency
Position
58.29
EFB act2 type
Auto
Transparent
General
Torque
Speed
Frequency
Position
58.30
EFB status word
transparent source
Not selected
Other
58.31
EFB act1
transparent source
Not selected
Other
ghv Vertriebs-GmbH | Am Schammacher Feld 47 | 85567 Grafing | Telefon + 49 80 92 81 89 0 | info@ghv.de | www.ghv.de
Description
Selects the type/source and scaling of actual value 1
transmitted to the fieldbus network through the embedded
fieldbus interface.
Type/source and scaling follow the type of reference 1
selected by parameter
58.26 EFB ref1
settings below for the sources and scalings.
The value selected by parameter
source
is sent as actual value 1. No scaling is applied (the 16-
bit scaling is 1 = 1 unit).
The value selected by parameter
source
is sent as actual value 1 with a 16-bit scaling of 100 =
1 unit (ie. integer and two decimals).
01.10 Motor torque
is sent as actual value 1. The scaling is
defined by parameter
46.03 Torque
01.01 Motor speed used
is sent as actual value 1. The scaling
is defined by parameter
46.01 Speed
01.06 Output frequency
is sent as actual value 1. The scaling
is defined by parameter
46.02 Frequency
Motor position is sent as actual value 1. See parameter
Motor position
scaled.
Selects the type/source and scaling of actual value 2
transmitted to the fieldbus network through the embedded
fieldbus interface.
Type/source and scaling follow the type of reference 2
selected by parameter
58.27 EFB ref2
settings below for the sources and scalings.
The value selected by parameter
source
is sent as actual value 2. No scaling is applied (the 16-
bit scaling is 1 = 1 unit).
The value selected by parameter
source
is sent as actual value 2 with a 16-bit scaling of 100 =
1 unit (ie. integer and two decimals).
01.10 Motor torque
is sent as actual value 2. The scaling is
defined by parameter
46.03 Torque
01.01 Motor speed used
is sent as actual value 2. The scaling
is defined by parameter
46.01 Speed
01.06 Output frequency
is sent as actual value 2. The scaling
is defined by parameter
46.02 Frequency
Motor position is sent as actual value 2. See parameter
Motor position
scaled.
Selects the source of the status word when
profile
is set to Transparent.
None.
Source selection (see
Terms and abbreviations
Selects the source of actual value 1 when
type
is set to
Transparent
None.
Source selection (see
Terms and abbreviations
type. See the individual
58.31 EFB act1 transparent
58.31 EFB act1 transparent
scaling.
scaling.
scaling.
type. See the individual
58.32 EFB act2 transparent
58.32 EFB act2 transparent
scaling.
scaling.
scaling.
58.25 Control
on page 112). -
58.28 EFB act1
or General.
on page 112). -
Def/FbEq16
Auto
0
1
2
3
4
5
90.06
6
Torque
0
1
2
3
4
5
90.06
6
Not selected
0
Not selected
0