180 Parameters
No.
Name/Value
14.76
AO1 actual value
0.000 ... 22.000 mA Value of AO1.
14.77
AO1 source
Zero
Motor speed used
Output frequency
Motor current
Motor torque
DC voltage
Power inu out
Speed ref ramp in
Speed ref ramp out
Speed ref used
Torq ref used
Freq ref used
Process PID out
Process PID fbk
Process PID act
Process PID dev
Force Pt100
excitation
Force KTY84
excitation
Force PTC
excitation
Force Pt1000
excitation
AO1 data storage
AO2 data storage
Other
14.78
AO1 force data
0.000 ... 22.000 mA Forced value of analog output AO1.
ghv Vertriebs-GmbH | Am Schammacher Feld 47 | 85567 Grafing | Telefon + 49 80 92 81 89 0 | info@ghv.de | www.ghv.de
Description
(Visible when
14.01 Module 1 type
Displays the value of AO1 in mA.
This parameter is read-only.
(Visible when
14.01 Module 1 type
Selects a signal to be connected to analog output AO1.
Alternatively, sets the output to excitation mode to feed a
constant current to a temperature sensor.
None.
01.01 Motor speed used
(page 115).
01.06 Output frequency
(page 115).
01.07 Motor current
(page 115).
01.10 Motor torque
(page 115).
01.11 DC voltage
(page 115).
01.14 Output power
(page 116).
23.01 Speed ref ramp input
23.02 Speed ref ramp output
24.01 Used speed reference
26.02 Torque reference used
28.02 Frequency ref ramp output
40.01 Process PID output actual
40.02 Process PID feedback actual
40.03 Process PID setpoint actual
40.04 Process PID deviation actual
The output is used to feed an excitation current to 1...3 Pt100
sensors. See section
Motor thermal protection
The output is used to feed an excitation current to a KTY84
sensor. See section
Motor thermal protection
The output is used to feed an excitation current to 1...3 PTC
sensors. See section
Motor thermal protection
The output is used to feed an excitation current to 1...3
Pt1000 sensors. See section
80).
13.91 AO1 data storage
(page 165).
13.92 AO2 data storage
(page 165).
Source selection (see
Terms and abbreviations
(Visible when
14.01 Module 1 type
Forced value that can be used instead of the selected output
signal. See parameter
14.71 AO force
=
FIO-11
or FAIO-01)
=
FIO-11
or FAIO-01)
(page 218).
(page 218).
(page 224).
(page 240).
(page 246).
(page 306).
(page 306).
(page 306).
(page 307).
(page 80).
(page 80).
(page 80).
Motor thermal protection
on page 112). -
=
FIO-11
or FAIO-01)
selection.
Def/FbEq16
-
1000 = 1 mA
Zero
0
1
3
4
6
7
8
10
11
12
13
14
16
17
18
19
20
21
22
23
(page
37
38
0.000 mA
1000 = 1 mA