ABB ACS880 Firmware Manual page 380

Primary control program
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

380 Parameters
No.
Name/Value
62.41
M/F follower ready
status 1
Bit
Name
0
Follower 1
1
Follower 2
...
...
15
Follower 16
0000h...FFFFh
62.42
M/F follower ready
status 2
Bit
Name
0
Follower 17
1
Follower 18
...
...
15
Follower 32
0000h...FFFFh
62.45
Data set 1 data 1
selection
None
CW 16bit
Ref1 16bit
Ref2 16bit
Other
62.46
Data set 1 data 2
selection
62.47
Data set 1 data 3
selection
...
...
62.50
Data set 3 data 3
selection
ghv Vertriebs-GmbH | Am Schammacher Feld 47 | 85567 Grafing | Telefon + 49 80 92 81 89 0 | info@ghv.de | www.ghv.de
Description
In the master, displays the ready status of the communication
with followers specified by parameter
supervision sel
1.
Description
1 = Follower 1 ready.
1 = Follower 2 ready.
...
1 = Follower 16 ready.
Follower 1...16 ready status.
In the master, displays the ready status of the communication
with followers specified by parameter
supervision sel
2.
Description
1 = Follower 17 ready.
1 = Follower 18 ready.
...
1 = Follower 32 ready.
Follower 17...32 ready status.
Parameters
62.45...62.50
in data sets 1 and 3 from the external controller. These data
sets are used in ModuleBus communication with a "standard
drive"
(60.50 DDCS controller drive type
drive).
Parameters
62.95...62.100
external controller in integer format, and can be used as
sources by other parameters.
For example, this parameter selects a target for word 1 of data
set 1. Parameter
62.95 Data set 1 data 1 value
received data in integer format, and can also be used as a
source by other parameters.
None.
Control Word (16 bits)
Reference REF1 (16 bits)
Reference REF2 (16 bits)
Source selection (see
Terms and abbreviations
Defines a target for the data received as word 2 of data set 1.
See also parameter
62.96 Data set 1 data 2
For the selections, see parameter
selection.
See parameter
62.45 Data set 1 data 1
...
See parameter
62.45 Data set 1 data 1
60.23 M/F status
60.24 M/F status
define a target for the data received
=
ABB standard
display the data received from the
displays the
on page 112). -
value.
62.45 Data set 1 data 1
selection.
selection.
Def/FbEq16
-
1 = 1
-
1 = 1
None
0
1
2
3
None
None
...
None

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents