548 Fieldbus control through the embedded fieldbus interface (EFB)
Bit
Name
8
JOGGING_1
9
JOGGING_2
10
REMOTE_
CMD
11
EXT_CTRL_
LOC
12...15 Reserved
ghv Vertriebs-GmbH | Am Schammacher Feld 47 | 85567 Grafing | Telefon + 49 80 92 81 89 0 | info@ghv.de | www.ghv.de
Value STATE/Description
1
Accelerate to jogging 1 reference.
Notes:
• Bits 4...6 must be 0.
• See also section
0
Jogging 1 disabled.
1
Accelerate to jogging 2 reference.
See notes at bit 8.
0
Jogging 2 disabled.
1
Fieldbus control enabled.
0
Control word and reference will not get through to the
drive, except for CW bits OFF1, OFF2 and OFF3.
1
Select External Control Location EXT2. Effective if the
control location is parameterized to be selected from the
fieldbus.
0
Select External Control Location EXT1. Effective if the
control location is parameterized to be selected from the
fieldbus.