User Load Curve - ABB ACS880 Firmware Manual

Primary control program
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name/Value
36.44
AL2 40 to 50%
0.00 ... 100.00%
36.45
AL2 50 to 60%
0.00 ... 100.00%
36.46
AL2 60 to 70%
0.00 ... 100.00%
36.47
AL2 70 to 80%
0.00 ... 100.00%
36.48
AL2 80 to 90%
0.00 ... 100.00%
36.49
AL2 over 90%
0.00 ... 100.00%
36.50
AL2 reset date
-
36.51
AL2 reset time
-
37

37 User load curve

37.01
ULC output status
word
Bit
Name
0
Under load limit
1
Reserved
2
Over load limit
3...15
Reserved
000b ... 101b
37.02
ULC supervision
signal
Not selected
Motor current %
Motor torque %
Output power % of
motor nominal
Other
ghv Vertriebs-GmbH | Am Schammacher Feld 47 | 85567 Grafing | Telefon + 49 80 92 81 89 0 | info@ghv.de | www.ghv.de
Description
Displays the percentage of samples recorded by amplitude
logger 2 that fall between 40 and 50%.
Amplitude logger 2 samples between 40 and 50%.
Displays the percentage of samples recorded by amplitude
logger 2 that fall between 50 and 60%.
Amplitude logger 2 samples between 50 and 60%.
Displays the percentage of samples recorded by amplitude
logger 2 that fall between 60 and 70%.
Amplitude logger 2 samples between 60 and 70%.
Displays the percentage of samples recorded by amplitude
logger 2 that fall between 70 and 80%.
Amplitude logger 2 samples between 70 and 80%.
Displays the percentage of samples recorded by amplitude
logger 2 that fall between 80 and 90%.
Amplitude logger 2 samples between 80 and 90%.
Displays the percentage of samples recorded by amplitude
logger 2 that exceed 90%.
Amplitude logger 2 samples over 90%.
Displays the date on which amplitude logger 2 was last reset.
Last reset date of amplitude logger 2.
Displays the time at which amplitude logger 2 was last reset.
Last reset time of amplitude logger 2.
Settings for user load curve.
See also section
User load curve
Displays the status of the monitored signal. (The status word
is independent of the actions and delays selected by
parameters 37.03, 37.04,
This parameter is read-only.
Information
1 = Monitored signal is below the underload curve
1 = Monitored signal is above the overload curve
Status of the monitored signal.
Selects the signal to be monitored. The function compares the
absolute value of the signal against the load curve.
No signal selected (monitoring disabled).
01.07 Motor current
(see page 115).
01.10 Motor torque
(see page 115).
01.15 Output power % of motor nom
Source selection (see
Terms and abbreviations
(page 83).
37.41
and 37.42.)
(see page 116).
on page 112). -
Parameters 303
Def/FbEq16
0.00%
1 = 1%
0.00%
1 = 1%
0.00%
1 = 1%
0.00%
1 = 1%
0.00%
1 = 1%
0.00%
1 = 1%
-
-
-
-
-
1 = 1
Not selected
0
2
3
4