ABB ACS880 Firmware Manual page 415

Primary control program
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name/Value
Restore defaults
Clear all
Reset all fieldbus
settings
96.07
Parameter save
manually
Done
Save
96.08
Control board boot
0...1
96.09
FSO reboot
False
True
ghv Vertriebs-GmbH | Am Schammacher Feld 47 | 85567 Grafing | Telefon + 49 80 92 81 89 0 | info@ghv.de | www.ghv.de
Description
All editable parameter values are restored to default values,
except
• motor data and ID run results
• parameter
31.42 Overcurrent fault limit
• control panel/PC communication settings
• I/O extension module settings
• fieldbus adapter settings
• encoder configuration data
• application macro selection and the parameter defaults
implemented by it
• parameter
95.01 Supply voltage
• parameter
95.09 Switch fuse controller
• differentiated defaults implemented by parameters
HW options word 1
and
• user lock configuration parameters 96.100...96.102.
All editable parameter values are restored to default values,
except
• control panel/PC communication settings
• application macro selection and the parameter defaults
implemented by it
• parameter
95.01 Supply voltage
• parameter
95.09 Switch fuse controller
• differentiated defaults implemented by parameters
HW options word 1
and
• user lock configuration parameters 96.100...96.102.
PC tool communication is interrupted during the restoring.
Note: Activating this selection will restore the default settings
of the fieldbus adapter if one is connected, potentially
including settings that cannot be accessed through drive
parameters.
Fieldbus adapter and embedded fieldbus interface settings
(parameter groups 50...58) are restored to default values.
This will also restore the default settings of the fieldbus
adapter if one is connected, potentially including settings that
cannot be accessed through drive parameters.
Saves the valid parameter values to permanent memory. This
parameter should be used to store values sent from a
fieldbus, or when using an external power supply to the
control board as the supply might have a very short hold-up
time when powered off.
Note: A new parameter value is saved automatically when
changed from the PC tool or control panel but not when
altered through a fieldbus adapter connection.
Save completed.
Save in progress.
Changing the value of this parameter to 1 reboots the control
unit (without requiring a power off/on cycle of the complete
drive module).
The value reverts to 0 automatically.
1 = Reboot the control unit.
Changing the value of (or the source selected by) this
parameter from 0 to 1 reboots the optional FSO-xx safety
functions module.
Note: The value does not revert to 0 automatically.
0.
1.
95.21 HW options word 2
95.21 HW options word 2
Parameters 415
Def/FbEq16
8
95.20
62
95.20
32
Done
0
1
0
1 = 1