No.
Name/Value
14.22
DIO3 ON delay
0.00 ... 3000.00 s
14.22
AI force selection
Bit
Name
0
AI1
1
AI2
2
AI3
3...15
Reserved
0000b...0111b
14.23
DI3 OFF delay
0.00 ... 3000.00 s
14.23
DIO3 OFF delay
0.00 ... 3000.00 s
14.24
DIO4 function
Output
Input
14.26
DIO4 output source
14.26
AI1 actual value
-22.000 ... 22.000
mA or V
14.27
DIO4 ON delay
0.00 ... 3000.00 s
ghv Vertriebs-GmbH | Am Schammacher Feld 47 | 85567 Grafing | Telefon + 49 80 92 81 89 0 | info@ghv.de | www.ghv.de
Description
(Visible when
14.01 Module 1 type
Defines the activation delay for digital input/output DIO3. See
parameter
14.12 DIO1 ON
Activation delay for DIO3.
(Visible when
14.01 Module 1 type
The true readings of the analog inputs can be overridden for
eg. testing purposes. A forced value parameter is provided for
each analog input, and its value is applied whenever the
corresponding bit in this parameter is 1.
Description
1 = Force mode: Force AI1 to value of parameter
1 = Force mode: Force AI2 to value of parameter
1 = Force mode: Force AI3 to value of parameter
(FIO-11 only).
Forced values selector for analog inputs.
(Visible when
14.01 Module 1 type
Defines the deactivation delay for digital input DI3. See
parameter
14.12 DI1 ON
delay.
Deactivation delay for DI3.
(Visible when
14.01 Module 1 type
Defines the deactivation delay for digital input/output DIO3.
See parameter
14.12 DIO1 ON
Deactivation delay for DIO3.
(Visible when
14.01 Module 1 type
Selects whether DIO4 of the extension module is used as a
digital input or output.
DIO4 is used as a digital output.
DIO4 is used as a digital input.
(Visible when
14.01 Module 1 type
Selects a drive signal to be connected to digital input/output
DIO4 when parameter
14.24 DIO4 function
For the available selections, see parameter
source.
(Visible when
14.01 Module 1 type
Displays the value of analog input AI1 in mA or V (depending
on whether the input is set to current or voltage).
This parameter is read-only.
Value of analog input AI1.
(Visible when
14.01 Module 1 type
Defines the activation delay for digital input/output DIO4. See
parameter
14.12 DIO1 ON
Activation delay for DIO4.
=
FIO-01
or FIO-11)
delay.
=
FIO-11
or FAIO-01)
14.28 AI1 force
14.43 AI2 force
14.58 AI3 force data
= FDIO-01)
= FIO-01)
delay.
= FIO-01)
= FIO-01)
is set to Output.
14.11 DIO1 output
=
FIO-11
or FAIO-01)
=
FIO-01
or FIO-11)
delay.
Parameters 171
Def/FbEq16
0.00 s
10 = 1 s
0000b
data.
data.
1 = 1
0.00 s
10 = 1 s
0.00 s
10 = 1 s
Input
0
1
Not
energized
-
1000 = 1 mA
or V
0.00 s
10 = 1 s

Hide quick links: