ABB ACS880 Firmware Manual page 145

Primary control program
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name/Value
07.30
Adaptive program
status
Bit
Name
0
Initialized
1
Editing
2
Edit done
3
Running
4...13
Reserved
14
State changing
15
Faulted
0000h...FFFFh
07.40
IEC application Cpu
usage peak
0.0 ... 100.0%
07.41
IEC application Cpu
load average
0.0 ... 100.0%
07.51
Slot 1 option
module
No option
[module type]
07.52
Slot 2 option
module
No option
[module type]
07.53
Slot 3 option
module
No option
[module type]
07.106 LSU loading
package name
ghv Vertriebs-GmbH | Am Schammacher Feld 47 | 85567 Grafing | Telefon + 49 80 92 81 89 0 | info@ghv.de | www.ghv.de
Description
Shows the status of the adaptive program.
See section
Adaptive programming
Description
1 = Adaptive program initialized
1 = Adaptive program is being edited
1 = Editing of adaptive program finished
1 = Adaptive program running
Reserved
1 = Error in adaptive program
Adaptive program status.
(Only visible with option +N8010 [application
programmability])
Displays the peak loading of the microprocessor caused by
the application program. This parameter can, for example, be
used to check the effect of a given application program
functionality on the CPU load.
The value is in percent of an internal quota.
Can be reset from the control panel by keeping Reset
depressed for over 3 seconds.
Peak microprocessor loading caused by application program.
(Only visible with option +N8010 [application
programmability])
Displays the average loading of the microprocessor caused
by the application program. The value is in percent of an
internal quota.
Average microprocessor loading caused by application
program.
Displays the type of module detected in slot 1 of the drive
control unit.
No module detected.
Type of module detected.
Displays the type of module detected in slot 2 of the drive
control unit.
No module detected.
Type of module detected.
Displays the type of module detected in slot 3 of the drive
control unit.
No module detected.
Type of module detected.
(Only visible when IGBT supply unit control activated by
95.20)
Name of the loading package of the supply unit firmware.
Parameters 145
(page 27).
Def/FbEq16
-
1 = 1
-
10 = 1%
-
10 = 1%
No option
0
-
No option
0
-
No option
0
-
-