No.
Name/Value
46.05
Current scaling
0...30000 A
46.06
Speed ref zero
scaling
0.00 ... 30000.00
rpm
46.07
Frequency ref zero
scaling
0.00 ... 1000.00 Hz
46.11
Filter time motor
speed
0...20000 ms
46.12
Filter time output
frequency
0...20000 ms
46.13
Filter time motor
torque
0...20000 ms
46.14
Filter time power
out
0...20000 ms
ghv Vertriebs-GmbH | Am Schammacher Feld 47 | 85567 Grafing | Telefon + 49 80 92 81 89 0 | info@ghv.de | www.ghv.de
Description
Defines the 16-bit scaling of current parameters. The value of
this parameter corresponds to 10000 in fieldbus,
master/follower etc. communication.
Current corresponding to 10000 on fieldbus.
Defines a speed corresponding to a zero reference received
from fieldbus (either the embedded fieldbus interface, or
interface FBA A or FBA B). For example, with a setting of 500,
the fieldbus reference range of 0...20000 would correspond to
a speed of 500...[46.01] rpm.
Note: This parameter is effective only with the ABB Drives
communication profile.
Speed corresponding to minimum fieldbus reference.
Defines a frequency corresponding to a zero reference
received from fieldbus (either the embedded fieldbus
interface, or interface FBA A or FBA B). For example, with a
setting of 30, the fieldbus reference range of 0...20000 would
correspond to a speed of 30...[46.02] Hz.
Note: This parameter is effective only with the ABB Drives
communication profile.
Frequency corresponding to minimum fieldbus reference.
Defines a filter time for signals
Motor speed
estimated,
01.04 Encoder 1 speed filtered
01.05 Encoder 2 speed
filtered.
Motor speed signal filter time.
Defines a filter time for signal
Output frequency signal filter time.
Defines a filter time for signal
Motor torque signal filter time.
Defines a filter time for signal
Output power signal filter time.
Parameters 331
01.01 Motor speed
used,
01.06 Output
frequency.
01.10 Motor
torque.
01.14 Output
power.
Def/FbEq16
10000 A
1 = 1 A
0.00 rpm
1 = 1 rpm
0.00 Hz
10 = 1 Hz
01.02
500 ms
and
1 = 1 ms
500 ms
1 = 1 ms
100 ms
1 = 1 ms
100 ms
1 = 1 ms