No.
Name/Value
24.11
Speed correction
-10000.00 ...
10000.00 rpm
24.12
Speed error filter
time
0...10000 ms
24.13
RFE speed filter
Off
On
ghv Vertriebs-GmbH | Am Schammacher Feld 47 | 85567 Grafing | Telefon + 49 80 92 81 89 0 | info@ghv.de | www.ghv.de
Description
Defines a speed reference correction, ie. a value added to the
existing reference between ramping and limitation. This is
useful to trim the speed if necessary, for example to adjust
draw between sections of a paper machine.
Note: For safety reasons, the correction is not applied when
an emergency stop is active.
WARNING! If the speed reference correction exceeds
21.06 Zero speed
limit, a ramp stop may be
impossible. Make sure the correction is reduced or
removed when a ramp stop is required.
See the control chain diagram on page 579.
Speed reference correction.
Defines the time constant of the speed error low-pass filter.
If the used speed reference changes rapidly, the possible
interferences in the speed measurement can be filtered with
the speed error filter. Reducing the ripple with this filter may
cause speed controller tuning problems. A long filter time
constant and fast acceleration time contradict one another. A
very long filter time results in unstable control.
Speed error filtering time constant. 0 = filtering disabled.
Enables/disables resonance frequency filtering. The filtering is
configured by parameters 24.13...24.17.
The speed error value coming to the speed controller is
filtered by a common 2nd order band-elimination filter to
eliminate the amplification of mechanical resonance
frequencies.
Note: Tuning the resonance frequency filter requires a basic
understanding of frequency filters. Incorrect tuning can
amplify mechanical oscillations and damage the drive
hardware. To ensure the stability of the speed controller, stop
the drive or disable the filtering before changing the parameter
settings.
0 = Resonance frequency filtering disabled.
1 = Resonance frequency filtering enabled.
0.
1.
Parameters 225
Def/FbEq16
0.00 rpm
See par.
46.01
0 ms
1 = 1 ms
Off
0
1