No.
Name/Value
92.14
Revolution data
width
0...32
92.15
Transient filter
4880 Hz
2440 Hz
1220 Hz
Disabled
92.17
Accepted pulse freq
of encoder 1
0...300 kHz
92.21
Encoder cable fault
mode
A, B
A, B, Z
A+, A-, B+, B-
A+, A-, B+, B-, Z+,
Z-
92.23
Maximum pulse
waiting time
1...200 ms
ghv Vertriebs-GmbH | Am Schammacher Feld 47 | 85567 Grafing | Telefon + 49 80 92 81 89 0 | info@ghv.de | www.ghv.de
Description
(Visible when an absolute encoder is selected)
Defines the number of bits used in revolution counting with a
multiturn encoder. For example, a setting of 12 bits would
support counting up to 4096 revolutions.
The value is used when parameter
source
is set to EnDat,
Hiperface
92.11 Absolute position source
this parameter to a non-zero value activates multiturn data
requesting.
Note: With an EnDat or HIPERFACE encoder and FEN-11
FPGA version VIE12200 or later, this parameter is
automatically set upon validation of encoder settings
Encoder parameter
refresh).
Number of bits used in revolution count.
(Visible when a TTL, TTL+ or HTL encoder is selected)
Activates transient filtering for the encoder (changes in
direction of rotation are ignored above the selected pulse
frequency).
Change in direction of rotation allowed below 4880 Hz.
Change in direction of rotation allowed below 2440 Hz.
Change in direction of rotation allowed below 1220 Hz.
Change in direction of rotation allowed at any pulse frequency. 3
(Visible when parameter
92.01 Encoder 1 type
HTL
2)
Defines the maximum pulse frequency of encoder 1.
Pulse frequency.
(Visible when a TTL, TTL+ or HTL encoder is selected)
Selects which encoder cable channels and wires are
monitored for wiring faults.
A and B.
A, B and Z.
A+, A-, B+ and B-.
A+, A-, B+, B-, Z+ and Z-.
(Visible when parameter
92.01 Encoder 1 type
Determines a pulse waiting time used in speed calculation for
the encoder interface. If no pulse edges are detected within
this time, the measured speed is zeroed by the interface.
Increasing the setting can improve measuring performance
especially at low, near zero speeds.
Notes:
• The parameter is only supported by FEN-xx modules with
FPGA version VIEx 2000 or later. On older modules, the
pulse waiting time is fixed to 4 ms.
• The parameter only affects speed measurement. Position
is updated whenever a new pulse edge is detected. When
the measured speed from the interface is zero, the drive
updates its speed data based on position changes.
Maximum pulse waiting time.
Parameters 399
92.11 Absolute position
or SSI. When parameter
is set to Tamagawa, setting
(91.10
=
HTL 1
or
=
TTL
or HTL)
Def/FbEq16
0
1 = 1
4880 Hz
0
1
2
0 kHz
1 = 1 kHz
A, B
0
1
2
3
4 ms
1 = 1 ms

Hide quick links: