6 Adjustments
6.7.3 Related Parameters
Step
6
7
8
6.7.3 Related Parameters
The following parameters are set automatically. Manual adjustments are not required.
Parameter
Pn140
Pn141
Pn145
Pn146
6-50
Display after Operation
No settings related to the vibration suppression function will be changed during opera-
tion.
If the motor does not stop approximately 10 seconds after the setting changes, a timeout
error will result and the previous setting will be enabled again.
The vibration suppression function will be enabled when the parameter is set in step 6.
The motor response, however, will change when the motor comes to a stop with no refer-
ence input.
Model Following Control Selection
Model Following Control Gain
Vibration Suppression 1 Frequency A
Vibration Suppression 1 Frequency B
Keys
Press the
usual display and the frequency currently displayed
will be set for the vibration suppression function
Press the
Press the
sion function. The screen in step 1 will appear again.
Name
Operation
Key. The "Setting f" will change to
Error
Force
reference
Key to save the settings.
Key to complete the vibration suppres-
.