YASKAWA E-V Series User Manual page 300

Ac servo drives linear motor analog voltage and pulse train reference sgdv servopack
Hide thumbs Also See for E-V Series:
Table of Contents

Advertisement

Alarm:
Alarm Name
The SERVOPACK and servomo-
tor capacities do not match each
other.
A.040:
Parameter Setting
A SERVOPACK fault occurred.
Error 1
(The parameter setting
The parameter setting is out of
was out of the allowable
the specified range.
setting range.)
The electronics gear ratio is out
of the setting range.
The encoder output pulse (Pn281)
A.041:
is out of the setting range and
Encoder Output Pulse
does not satisfy the setting condi-
Setting Error
tions.
The speed of program JOG oper-
ation (Fn004) is lower than the
setting range after having
changed the electronic gear ratio
(Pn20E/Pn210) or the servomo-
tor.
The speed of program JOG oper-
A.042:
ation (Fn004) is lower than the
setting range after having
Parameter
changed the setting of Pn533
Combination Error
"Program JOG Movement
Speed."
The moving speed of advanced
autotuning is lower than the set-
ting range after having changed
the electronic gear ratio (Pn20E/
Pn210) or the servomotor.
A.044:
The setting of the option module
Fully-closed Loop
does not match with those of
Control Parameter
Pn00B.3 and Pn002.3.
Setting Error
The SERVOPACK and servomo-
tor capacities do not match each
A.050:
other.
Combination Error
(The SERVOPACK and
servomotor capacities do
An encoder fault occurred.
not correspond.)
A SERVOPACK fault occurred.
An unsupported serial converter
A.051:
unit, serial encoder, or linear
Unsupported Device
scale is connected to the SERVO-
Alarm
PACK.
∗1. Linear scale by Heidenhain or Renishaw :
Linear scale (ST78 A) by Mitutoyo
Cause
Investigative Actions
Check the combination of SERVO-
PACK and servomotor capacities.
Check the setting ranges of the
parameters that have been changed.
Check the electronic gear ratio. The
ratio must satisfy:
0.001< (Pn20E/Pn210) <4000.
Check the parameter Pn281.
Check that the detection conditions
is satisfied.
Check that the detection conditions
is satisfied.
Check that the detection conditions
is satisfied.
Check the settings of the option
module, Pn00B.3, and Pn002.3.
Check the capacities to see if they
satisfy the following condition:
(Servomotor capacity)/(SERVO-
PACK capacity) ≤ 1/4, or (Servo-
motor capacity)/(SERVOPACK
capacity) ≤ 4.
Replace the servomotor and see if
the alarm occurs again.
Check the product specifications,
and select the correct model.
Pn585
Pn282[µm]
Pn585
×
Pn282[µm]
Select the proper combination of
SERVOPACK and servomotor
capacities.
The SERVOPACK may be faulty.
Repair or replace the SERVO-
PACK.
Set the parameter to a value within
the specified range.
Set the electronic gear ratio in the
range: 0.001< (Pn20E/Pn210)
<4000.
Set Pn281 to a correct value.
Reduce the electronic gear ratio
*1
(Pn20E/Pn210).
Increase the setting for Pn533 "Pro-
*1
gram JOG Movement Speed."
Reduce the electronic gear ratio
*1
(Pn20E/Pn210).
The setting of option module must
be compatible with the settings of
Pn00B.3 and Pn002.3.
Mount an option module or replace
the mounted option module with an
appropriate model. Or change the
parameter setting.
Select the proper combination of
SERVOPACK and servomotor
capacities.
Replace the servomotor (encoder).
The SERVOPACK may be faulty.
Repair or replace the SERVO-
PACK.
Select the correct combination of
units.
256
Pn20E
×
7
10
Pn210
512
Pn20E
7
10
Pn210
9.1 Troubleshooting
Corrective Actions
9
9-7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SglgwSglfwSgtSgltwSglcw