7.13 Servomotor Model Display (Fn011)
This function is used to check the servomotor model, voltage, capacity, encoder type, and encoder resolution.
If the SERVOPACK has been custom-made, you can also check the specification codes of SERVOPACKs.
Follow the steps below.
Display after
Step
Operation
1
2
3
4
5
6
7
Keys
Press the MODE/SET Key to select the utility function
mode.
MODE/SET
DATA/
Press the UP or DOWN Key to select Fn011.
MODE/SET
DATA/
Press the DATA/SHIFT Key for approximately one second
to display the servomotor model and voltage code.
Servomotor Voltage
MODE/SET
DATA/
Press the MODE/SET Key to display the servomotor capac-
ity.
MODE/SET
DATA/
Press the MODE/SET Key, and the encoder type and reso-
lution code will be displayed.
MODE/SET
DATA/
Press the MODE/SET Key to display the SERVOPACK's
code for custom orders.
MODE/SET
DATA/
* The display "y.0000" means standard model.
Press the DATA/SHIFT Key for approximately one second.
"Fn011" is displayed again.
MODE/SET
DATA/
7.13 Servomotor Model Display (Fn011)
Operation
Servomotor Model
Type
Model
Data
Data
02
400 VAC
40
linear motor
01
200 VAC
Servomotor capacity in units of 10 W
The above example indicates 100 W
Encoder Type
Encoder Resolution
Type
Resolution
Data
Data
00
8
Incremental
Absolute
01
12
12-bit
Code for custom orders
8-bit
7
7-21