YASKAWA E-V Series User Manual page 343

Ac servo drives linear motor analog voltage and pulse train reference sgdv servopack
Hide thumbs Also See for E-V Series:
Table of Contents

Advertisement

Parameter
Name
No.
Input Signal Selection 2
4th
3rd
2nd
digit
digit
digit
n.
Pn50B
Setting
Range
0000 to FFFF
1st
digit
N-OT Signal Mapping (Overtravel when OFF (H-level))
0
Reverse run allowed when CN1-40 input signal is ON (L-level).
1
Reverse run allowed when CN1-41 input signal is ON (L-level).
2
Reverse run allowed when CN1-42 input signal is ON (L-level).
3
Reverse run allowed when CN1-43 input signal is ON (L-level) .
4
Reverse run allowed when CN1-44 input signal is ON (L-level).
5
Reverse run allowed when CN1-45 input signal is ON (L-level).
6
Reverse run allowed when CN1-46 input signal is ON (L-level).
7
Reverse run prohibited.
8
Reverse run allowed.
9
Reverse run allowed when CN1-40 input signal is OFF (H-level).
A
Reverse run allowed when CN1-41 input signal is OFF (H-level).
B
Reverse run allowed when CN1-42 input signal is OFF (H-level).
C
Reverse run allowed when CN1-43 input signal is OFF (H-level).
D
Reverse run allowed when CN1-44 input signal is OFF (H-level).
E
Reverse run allowed when CN1-45 input signal is OFF (H-level).
F
Reverse run allowed when CN1-46 input signal is OFF (H-level).
/ALM-RST Signal Mapping
(Alarm reset when OFF (H-level) to ON (L-level))
0
Active on the falling edge of CN1-40 input signal.
1
Active on the falling edge of CN1-41 input signal.
2
Active on the falling edge of CN1-42 input signal.
3
Active on the falling edge of CN1-43 input signal.
4
Active on the falling edge of CN1-44 input signal.
5
Active on the falling edge of CN1-45 input signal.
6
Active on the falling edge of CN1-46 input signal.
7
Reserved (Do not change.)
8
Sets signal OFF.
9
Active on the rising edge of CN1-40 input signal.
A
Active on the rising edge of CN1-41 input signal.
B
Active on the rising edge of CN1-42 input signal.
C
Active on the rising edge of CN1-43 input signal.
D
Active on the rising edge of CN1-44 input signal.
E
Active on the rising edge of CN1-45 input signal.
F
Active on the rising edge of CN1-46 input signal.
/P-CL Signal Mapping (Force Limit when ON (L-level))
0 to F Same as /S-ON, the setting of 2nd digit of Pn50A
/N-CL Signal Mapping (Force Limit when ON (L-level))
0 to F Same as /S-ON, the setting of 2nd digit of Pn50A
Factory
When
Units
Setting
Enabled
6543
After restart
10.2 List of Parameters
Reference
Classification
Section
Setup
(Refer to 5.2.3)
(Refer to 5.2.3.)
(Refer to 5.10.1)
(Refer to 5.10.1.)
(Refer to 5.8.2)
(Refer to 5.8.2.)
(Refer to 5.8.2.)
(Refer to 5.8.2)
10-23
10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SglgwSglfwSgtSgltwSglcw

Table of Contents