Software Reset (Fn030) - YASKAWA E-V Series User Manual

Ac servo drives linear motor analog voltage and pulse train reference sgdv servopack
Hide thumbs Also See for E-V Series:
Table of Contents

Advertisement

7.20 Software Reset (Fn030)

This function enables resetting the SERVOPACK internally from software. If this function is used when
parameter changes have been made that require turning the power OFF and ON, the changes will be reflected
without actually turning the power OFF and ON.
Follow the steps below to reset the SERVOPACK internally.
Display after
Step
Operation
1
2
3
4
Display after operation
5
6
• Starts software reset operation with the servo OFF.
• This function resets the SERVOPACK independently of host controller. Be sure to
confirm that resetting the SERVOPACK has no influence the operation of host control-
ler.
Keys
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
Operation
Press the MODE/SET Key to select the utility function
mode.
Press the UP or DOWN Key to select Fn030.
Press the DATE/SHIFT key for approximately one second.
The display shown on the left appears.
Press the UP Key until "SrSt5" is displayed.
Note:
If there is a mistake during key operations, "nO_OP" will be
displayed for approximately one second and then "Fn030"
will be displayed again.
Press the MODE/SET Key. The panel display will disap-
pear.
Note:
This function cannot be executed while the servo is ON.
The status display screen, which is the same as the screen
that is displayed immediately after the power turned ON,
will appear.

7.20 Software Reset (Fn030)

7-33
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SglgwSglfwSgtSgltwSglcw

Table of Contents