5.9.5 Origin Setting (Fn020)

The origin setting function is used to set the current position as the origin. After executing this function once,
origin setting is not necessary every time the power is turned ON, so an immediate start of operation is possi-
ble.
Follow the steps below to detect the polarity.
• After execution of origin setting, the servo ready (/S-RDY) signal will become inactive and the servo will be
unable to draw power since the system position data will have been changed. Always turn the power sup-
ply OFF and then ON again after execution of origin setting.
• After execution of origin setting, the servomotor phase data in the SERVOPACK will be discarded. Exe-
cute polarity detection (Fn080) again to save the servomotor phase data in the SERVOPACK.
(1) Settings before Operation
The following settings are required before setting origin.
• If the S-ON input signal is ON, turn OFF the signal.
• If Pn50A.1 is set to 7 (i.e., the servo is always ON), change the value.
(2) Operating Procedure
Display after
Step
Operation
1
2
3
4
5
6
7
8
Turn OFF the power and then turn ON again to validate the setting.
IMPORTANT
Keys
Press the MODE/SET Key to select the utility function
mode.
MODE/SET
DATA/
Press the UP or the DOWN Key to select Fn020.
MODE/SET
DATA/
Press the DATA/SHIFT Key for approximately one second.
The display shown on the left appears.
MODE/SET
DATA/
Press the UP Key until "OSET5" is displayed.
Note:
If there is a mistake during key operations. "NO_OP" will
MODE/SET
DATA/
be displayed for approximately one second and then
"Fn000" will be displayed again.
Press the MODE/SET Key to set the origin of the scale.
After the setting is completed, "donE" will blink for approx-
imately one second.
MODE/SET
DATA/
After one second
After "donE" is displayed, "OSET5" is displayed again.
Press the DATA/SHIFT Key for approximately one second.
"Fn020" is displayed again.