7 Utility Functions (Fn
(2) Operating Procedure
Follow the steps below to perform the manual gain-adjustment of analog monitor output.
Step
1
2
3
4
5
6
7
8
7-16
)
Display after
Operation
MODE/SET
MODE/SET
MODE/SET
MODE/SET
MODE/SET
MODE/SET
MODE/SET
MODE/SET
Keys
Press the MODE/SET Key to select the utility function
mode.
DATA/
Press the UP or DOWN Key to select Fn00D.
DATA/
Press the DATA/SHIFT Key for approximately one second.
The display shown on the left appears.
DATA/
Press the MODE/SET Key to select channel-1 or channel-2
monitor output.
DATA/
Press the DATA/SHIFT Key for less than one second. Gain
adjustment data will be displayed as shown on the left.
DATA/
Press the UP or DOWN Key to change the data. This com-
pletes gain adjustment of the analog monitor output.
DATA/
Press the DATA/SHIFT Key for less than one second. The
gain adjustment data will be displayed as shown on the left.
To adjust a different channel, switch the monitor channel
using steps 4 through 6.
DATA/
Press the DATA/SHIFT Key for approximately one second.
"Fn00D" is displayed again.
DATA/