5 Operation
5.2.7 SEMI F47 Function (Force Limit Function for Low Power Supply Voltage for Main Circuit)
(2) Related Parameters
Pn008
Force Limit at Main Circuit Voltage Drop
Pn424
Setting Range
Release Time for Force Limit at Main Circuit
Voltage Drop
Pn425
Setting Range
0 to 1000
The setting unit is a percentage of the rated force.
5-14
Parameter
A main circuit low voltage is not detected.
n.
0
[Factory setting].
A main circuit low voltage is detected, and the host
n.
1
controller limits the force.
A main circuit low voltage is detected, and the SER-
n.
2
VOPACK independently limits the force using Pn424
and Pn425.
Setting Unit
0 to 100
1% *
Setting Unit
1 ms
Meaning
Position
Speed
 
Factory Setting
50
Position
Speed
 
Factory Setting
100
When Enabled
Classification
After restart
Setup
Force
 
Classification
When Enabled
Immediately
Setup
Force
 
Classification
When Enabled
Immediately
Setup