List Of Alarms; Troubleshooting - YASKAWA E-V Series User Manual

Ac servo drives linear motor analog voltage and pulse train reference sgdv servopack
Hide thumbs Also See for E-V Series:
Table of Contents

Advertisement

9 Troubleshooting

9.1.1 List of Alarms

9.1
Troubleshooting
The following sections describe troubleshooting in response to alarm displays.
The alarm name, alarm meaning, alarm stopping method, alarm reset capability and alarm code output are
listed in order of the alarm numbers in 9.1.1 List of Alarms.
The causes of alarms and troubleshooting methods are provided in 9.1.2 Troubleshooting of Alarms.
9.1.1 List of Alarms
If an alarm occurs, the servomotor can be stopped by doing either of the following operations.
Gr.1: The servomotor is stopped according to the settings in Pn001.0 if an alarm occurs. Pn001.0 is factory-set
to stop the servomotor by applying the DB.
Gr.2: The servomotor is stopped according to the setting in Pn00B.1 if an alarm occurs. Pn00B.1 is factory-set
to stop the servomotor by setting the speed reference to
always use the Gr.1 method to stop. By setting Pn00B.1 to 1, the servomotor stops using the same
method as Gr.1. When coordinating a number of servomotors, use this alarm stop method to prevent
machine damage that may result due to differences in the stop method.
Alarm
Alarm Name
Display
Parameter Checksum
A.020
Error 1
A.021
Parameter Format Error 1
A.022
System Checksum Error 1
Parameter Password Error
A.023
1
A.030
Main Circuit Detector Error Detection data for power circuit is incorrect.
A.040
Parameter Setting Error 1
Encoder Output Pulse
A.041
Setting Error
Parameter Combination
A.042
Error
Fully-closed Loop Control
A.044
Parameter Setting Error
A.050
Combination Error
A.051
Unsupported Device Alarm
Linear Scale Pitch Setting
A.080
Error
Cancelled Servo ON
A.0b0
Command Alarm
Overcurrent or Heat Sink
A.100
Overheated
9-2
Meaning
The data of the parameter in the SERVO-
PACK is incorrect.
The data of the parameter in the SERVO-
PACK is incorrect.
The data of the parameter in the SERVO-
PACK is incorrect.
The data of the parameter in the SERVO-
PACK is incorrect.
The parameter setting is outside the allow-
able setting range.
The encoder output pulse setting (pulse
unit) (Pn212) is outside the allowable set-
ting range or not satisfies the setting condi-
tions.
Combination of some parameters exceeds
the setting range.
The settings of the option module and
Pn00B.3, Pn002.3 do not match.
The SERVOPACK and the servomotor
capacities do not match each other.
The device unit unsupported was con-
nected.
The setting of the linear scale pitch (Pn282)
has not been changed from the default set-
ting.
The Host controller reference was sent to
turn the Servo ON after the Servo ON func-
tion was used with the utility function.
An overcurrent flowed through the IGBT.
Heat sink of the SERVOPACK was over-
heated.
0.
The servomotor under force control will
"
"
Servo-
Alarm Code Output
motor
Alarm
Stop
Reset
ALO1 ALO2 ALO3
Method
Gr.1
N/A
Gr.1
N/A
Gr.1
N/A
Gr.1
N/A
Gr.1
Available
Gr.1
N/A
Gr.1
N/A
Gr.1
N/A
Gr.1
N/A
Gr.1
Available
Gr.1
N/A
Gr.1
N/A
Gr.1
Available
Gr.1
N/A
H
H
H
L
H