YASKAWA E-V Series User Manual page 194

Ac servo drives linear motor analog voltage and pulse train reference sgdv servopack
Hide thumbs Also See for E-V Series:
Table of Contents

Advertisement

(3) Operating Procedure with Panel Operator
Step
Display after Operation
1
2
3
4
5
6
7
(Display blinks)
8
Keys
Press the MODE/SET Key to select the utility func-
tion mode.
MODE/SET
DATA/
Press the UP or the DOWN Key to select the Fn200.
MODE/SET
DATA/
Press the MODE/SET Key to change to setting
screen.
Note: If the display does not switch and NO-OP is
displayed, the write prohibited setting is set in
MODE/SET
DATA/
Fn010. Change the setting in Fn010 and press
the key again after enabling writing.
If the noise is generated, change the setting using the
UP Key.
MODE/SET
DATA/
Press the DATA/SHIFT Key for approximately one
second to change to tuning level setting screen.
MODE/SET
DATA/
Press the UP or the DOWN Key to select the tuning
level.
Select the tuning level from 0 to 4. The larger the
value, the higher the gain is and the better response
performance will be. (The factory setting is 4.)
Note: Vibration may occur if the tuning level is too
high. Lower the tuning level if vibration
occurs.
MODE/SET
DATA/
If high-frequency noise is generated, press the DATA/
SHIFT Key to automatically set a notch filter for the
vibration frequency. If the tuning level is changed,
the automatically set notch filter will be canceled. If
vibration occurs, however, the notch filter will be set
again.
Press the MODE/SET Key. "donE" will blink and the
settings will be saved in EEPROM.
MODE/SET
DATA/
Press the DATA/SHIFT Key for more than one sec-
ond. "Fn200" is displayed again.
MODE/SET
DATA/
6.2 Tuning-less Function
Operation
6
6-13