6.1.2
List of MECHATROLINK-III Common Parameters
The types of motors to which the parameter applies.
All: The parameter is used for both Rotary Servomotors and Linear Servomotors.
Rotary: The parameter is used for only Rotary Servomotors.
Linear: The parameter is used for only Linear Servomotors.
Rotary Servomotor terms are used for parameters that are
applicable to all Servomotors. If you are using a Linear Servomotor,
you need to interpret the terms accordingly. Refer to the following
section for details.
Parameter
Size
No.
61
4
PnAC2
Differences in Terms for Rotary Servomotors and
Linear Servomotors
on page xi
Setting
Name
Range
1,000 to
Speed Loop Gain
2,000,000
6.1 List of Servo Parameters
6.1.2 List of MECHATROLINK-III Common Parameters
Indicates when a change to the
parameter will be effective.
"After restart" indicates parameters
that will be effective after one of the
following is executed.
• The power supply is turned OFF
and ON again.
• The CONFIG command is sent.
• A software reset is executed.
Setting Unit
Default
Applicable
[Resolution]
Setting
Motors
0.001 Hz
40000
[0.1 Hz]
You can set the parameter in increments of
the setting unit.
However, if a unit is given in square brackets,
the setting is automatically converted to the
resolution given in the square brackets.
When
Classi-
Enabled
fication
Immedi-
All
Tuning
ately
6
6-3